One or two stage horizontal radial pumps. With a dual-flow
impeller design or a combination of two mirror radial impellers, or a dual-flow
impeller and radial impeller. Radially and axially split spiral cabinet.
Horizontal, axially split single-stage pump with a radial dual-flow impeller. Bearings lubricated with grease. Seal chamber designed for installation of compressed seals, mechanical seals, folded or cassette structures, including the installation of a double seal.
ISO 5199, EU directive ATEX 2014/34/EU
Technical specfications
Q max = 7500 m3/h
H max = 190 m
T max = 80 °C
Application
Pumps are used in chemical and petrochemical plants and
power plant’s cooling systems. Drinking and service water networks.
Installations of fire systems and irrigation stations. Vertical design can be
used to reduce space requirements.
Modification
Vertical design with one seal
Impeller with overlapped blades
Dual flow pump CD2
Horizontal, radially split single-stage pump or two-stage pump with radial impeller. Between bearing version. Pump design is in accordance with API 610-BB2. Bearings are lubricated with oil bath. Seal chamber designed for the installation of mechanical cassette seals according to API 682. Bearing bracket are equipped with ribs for intensifying heat transfer.
API 610/ISO 13709, EU directive ATEX 2014/34/EU
Technical specfications
Q max = 1750 m3/h
H max = 300 m
T max = 450 °C